Difference Between RFOU and BFOU Cable

Offshore and marine electrical installations operate in some of the most demanding environments. Electrical cables used in these applications must withstand extreme temperatures, moisture, saltwater exposure, oil, drilling mud, mechanical stress, and potential fire hazards.

Two commonly used offshore cable types are RFOU and BFOU cables. Both are designed for demanding marine and offshore installations, offering halogen-free construction, mud resistance, and specialised fire safety properties. However, their most important difference lies in their fire performance.

RFOU cables are flame-retardant, whereas BFOU cables are fire-resistant and designed to maintain electrical circuit integrity during specified fire exposure conditions.

Understanding the difference between RFOU and BFOU cables helps electrical engineers, offshore contractors, procurement professionals, and marine equipment buyers select the appropriate cable for their installation requirements.

What Are RFOU and BFOU Cables?

RFOU and BFOU are specialised offshore power and instrumentation cables manufactured for fixed installations in marine environments, offshore platforms, oil and gas facilities, and other demanding industrial applications.

Both cable types are commonly manufactured according to NEK TS 606 requirements and relevant IEC 60092 standards. They are designed to provide reliable electrical performance while offering protection against harsh environmental conditions.

Their common characteristics include:

  • Halogen-free construction.
  • Low smoke emission properties.
  • Resistance to oil and drilling mud.
  • Tinned copper conductors.
  • Specialised insulation and sheath materials.
  • Mechanical protection through suitable screening or armour arrangements.
  • Suitability for demanding marine and offshore environments.

Although both cable types share similar construction characteristics, their fire performance requirements distinguish them from one another.

What Is an RFOU Cable?

An RFOU cable is a flame-retardant offshore cable designed to reduce fire propagation and limit the contribution of cables to fire development.

These cables are commonly used in offshore power distribution, instrumentation, communication, control, and alarm systems where maintaining circuit operation during direct fire exposure is not a specified requirement.

RFOU cables are designed to meet applicable flame propagation requirements, including relevant IEC 60332 testing.

Key Features of RFOU Cables

  • Flame-retardant performance.
  • Low smoke emission.
  • Halogen-free insulation and sheathing.
  • Resistance to oil and drilling mud.
  • Tinned copper conductor construction.
  • Suitable for marine and offshore fixed installations.
  • Available in power and instrumentation configurations.

Common Applications of RFOU Cables

RFOU cables are suitable for various offshore electrical installations, including:

  1. General power distribution.
  2. Instrumentation and monitoring systems.
  3. Communication and telecommunications.
  4. Control and alarm circuits.
  5. Non-emergency lighting systems.
  6. Industrial electrical equipment.
  7. Fixed electrical installations on ships and offshore platforms.

Their flame-retardant properties help prevent fire from spreading along cable routes, making them suitable for applications where fire containment is the primary cable-related requirement.

What Is a BFOU Cable?

A BFOU cable is a fire-resistant offshore cable designed to maintain electrical continuity during specified fire exposure conditions.

Its most important construction feature is an additional Mica Glass Tape (MGT) layer wrapped around the conductors. This layer acts as a fire barrier, helping protect the electrical conductors and maintain circuit integrity when the cable is exposed to fire.

BFOU cables are designed for applications where electrical power or signal transmission must continue during a fire emergency.

They are commonly associated with IEC 60331 fire-resistance testing, depending on the applicable cable specification.

Key Features of BFOU Cables

  • Fire-resistant construction.
  • Additional Mica Glass Tape fire barrier.
  • Low smoke emission.
  • Halogen-free materials.
  • Resistance to oil and drilling mud.
  • Tinned copper conductor construction.
  • Suitable for critical offshore electrical systems.
  • Designed to maintain circuit integrity under specified fire conditions.

Common Applications of BFOU Cables

BFOU cables are commonly specified for critical electrical and safety-related installations, including:

  1. Emergency shutdown (ESD) systems.
  2. Fire detection and alarm systems.
  3. Emergency lighting circuits.
  4. Firefighting equipment power supplies.
  5. Critical instrumentation systems.
  6. Emergency communication systems.
  7. Essential electrical systems on offshore platforms and vessels.

Their fire-resistant construction makes them particularly important in applications where losing electrical power or signals during a fire could compromise personnel safety or emergency response.

What Is the Difference Between RFOU and BFOU Cable?

The main difference between RFOU and BFOU cables is their ability to maintain electrical continuity during fire exposure.

RFOU cables are designed to resist flame propagation, while BFOU cables incorporate an additional fire barrier that helps maintain circuit operation during specified fire conditions.

Here is a comparison of their major characteristics.

Comparison FactorRFOU CableBFOU Cable
Cable classificationFlame-retardantFire-resistant
Fire performanceHelps prevent flame propagationMaintains circuit integrity during specified fire exposure
Mica Glass TapeNot included in standard constructionAdditional MGT fire barrier
IEC fire testingRelevant IEC 60332 testsRelevant IEC 60331 tests
Smoke emissionLow smokeLow smoke
Halogen contentHalogen-freeHalogen-free
Mud resistanceAvailable in NEK 606 constructionsAvailable in NEK 606 constructions
Typical applicationsGeneral power, control and instrumentationEmergency and critical systems
Circuit continuity during fireNot guaranteedDesigned to maintain continuity during specified testing

The exact construction, approvals, and performance must always be verified against the manufacturer's technical datasheet.

Understanding the Fire Performance: IEC 60332 vs IEC 60331

To understand why RFOU and BFOU cables are used in different applications, it is important to distinguish between flame retardancy and fire resistance.

IEC 60332: Flame Retardant Cable Testing

IEC 60332 covers tests for the resistance of electric cables to the spread of fire under defined test conditions.

These tests evaluate how a cable or group of cables behaves when exposed to a controlled ignition source.

The objective is to assess flame propagation and determine whether the cable meets the relevant flame-retardancy requirements.

RFOU cables are designed to meet applicable flame propagation requirements, helping limit the spread of fire along cable installations.

However, flame retardancy does not mean that the cable will continue transmitting electrical power or signals during a fire.

IEC 60331: Fire Resistance Testing

IEC 60331 covers fire-resistance testing for cables required to maintain circuit integrity under specified fire conditions.

BFOU cables incorporate Mica Glass Tape around the conductors to provide an additional thermal barrier.

This construction helps protect the conductors and maintain electrical continuity during the applicable fire-resistance test.

This characteristic is particularly important for emergency electrical systems that must remain operational during a fire.

The exact test temperature, exposure duration, and other conditions depend on the applicable IEC 60331 test procedure and cable specification.

RFOU and BFOU Cable Construction

Although both cable types are designed for offshore environments, their internal construction differs in one important area.

RFOU Cable Construction

A typical RFOU cable construction includes:

  • Conductor: Class 2 stranded tinned copper.
  • Insulation: Ethylene Propylene Rubber (EPR).
  • Bedding: Halogen-free compound.
  • Screening or armour: Tinned Copper Wire Braid (TCWB), depending on design.
  • Outer sheath: SHF2 or specified SHF Mud-resistant compound.

Typical construction representation:

EPR / EPR / TCWB / EVA

BFOU Cable Construction

A typical BFOU cable construction includes an additional Mica Glass Tape layer around the conductors.

Its construction may include:

  • Conductor: Class 2 stranded tinned copper.
  • Fire barrier: Mica Glass Tape (MGT).
  • Insulation: Ethylene Propylene Rubber (EPR).
  • Bedding: Halogen-free compound.
  • Screening or armour: Tinned Copper Wire Braid (TCWB), depending on design.
  • Outer sheath: SHF2 or specified SHF Mud-resistant compound.

Typical construction representation:

MGT / EPR / EPR / TCWB / EVA

Actual layer arrangements and materials vary according to the manufacturer's design and the applicable NEK 606 cable type.

Shared Features of RFOU and BFOU Offshore Cables

Despite their different fire performance, RFOU and BFOU cables share several characteristics that make them suitable for demanding offshore installations.

1. Halogen-Free Construction

Both cable types are designed with halogen-free materials in accordance with their applicable specifications.

This helps reduce the release of corrosive halogen-containing gases during combustion, which is particularly important in enclosed marine and offshore environments.

2. Low Smoke Emission

Low smoke emission properties help reduce smoke generation during fire incidents.

Maintaining better visibility can support evacuation and emergency response in enclosed offshore installations.

3. Oil and Mud Resistance

Offshore cables may be exposed to drilling fluids, hydrocarbons, oils, and other industrial substances.

NEK 606 cable constructions can incorporate specialised mud-resistant outer sheaths designed to withstand these challenging environments.

4. Temperature Resistance

RFOU and BFOU cables are available in constructions designed for demanding temperature conditions.

A commonly specified operating temperature range for certain NEK 606 constructions is approximately -40°C to +90°C. Always verify the permitted range for the exact cable product.

5. Screening and Electromagnetic Protection

Instrumentation versions can be supplied with individual or collective screening arrangements.

Tinned copper wire braid screening helps reduce electromagnetic interference (EMI), supporting reliable signal transmission in industrial electrical environments.

How to Choose Between RFOU and BFOU Cables

Selecting between RFOU and BFOU cables depends primarily on the electrical system's requirements during an emergency.

Choose RFOU Cable When:

  • The installation requires flame-retardant offshore cable.
  • Preventing fire propagation is the primary requirement.
  • The connected system does not require continued operation during fire exposure.
  • The application involves general instrumentation, communication, or control.
  • The project specification permits flame-retardant cable construction.

Choose BFOU Cable When:

  • Electrical continuity must be maintained during a fire.
  • The cable supplies critical emergency equipment.
  • The installation involves emergency shutdown or fire detection systems.
  • Emergency lighting or other life-safety circuits require fire-resistant cabling.
  • The project specification requires compliance with applicable fire-resistance testing.

Important: Cable selection should always follow the project's engineering specifications, fire safety assessment, applicable offshore regulations, and approved cable datasheets. Not every emergency-related circuit automatically requires the same cable classification.

What Are the Common Voltage Ratings of RFOU and BFOU Cables?

RFOU and BFOU cables are available in different voltage configurations depending on their intended applications.

Common configurations include:

Power cables:

  • 0.6/1 kV.
  • Other medium-voltage RFOU variants are available depending on the manufacturer's product range and specification.

Instrumentation cables:

  • 150/250 V.
  • Individually screened configurations.
  • Collectively screened configurations.

For example, NEK 606 cable designations include:

  • RFOU P101: 0.6/1 kV power cable.
  • BFOU P105: 0.6/1 kV fire-resistant power cable.
  • RFOU(i) S101: 150/250 V individually screened instrumentation cable.
  • RFOU(c) S102: 150/250 V collectively screened instrumentation cable.
  • BFOU(i) S103: 150/250 V individually screened fire-resistant instrumentation cable.
  • BFOU(c) S104: 150/250 V collectively screened fire-resistant instrumentation cable.

The exact voltage rating, conductor size, number of cores, and screening arrangement should be confirmed through the product datasheet.

RFOU and BFOU cables are both important components of marine and offshore electrical installations. Although they share several construction characteristics, their fire performance makes them suitable for different applications.

RFOU cables provide flame-retardant performance, helping prevent fire propagation along cable routes. BFOU cables offer an additional level of protection through Mica Glass Tape construction, supporting continued power and signal transmission during specified fire exposure conditions.

For general offshore power, control, communication, and instrumentation applications where fire survival is not required, RFOU cables can be a suitable solution. For critical emergency systems that must maintain electrical continuity during a fire, BFOU cables are generally the more appropriate choice.

Ultimately, selecting the correct offshore cable requires evaluating electrical requirements, environmental conditions, fire safety expectations, and applicable NEK 606 and IEC standards. Always consult the manufacturer's technical documentation to confirm that the selected cable meets the project's requirements.

Frequently Asked Questions (FAQs)

1. What is the main difference between RFOU and BFOU cables?

RFOU cables are flame-retardant and designed to limit fire propagation. BFOU cables contain an additional Mica Glass Tape fire barrier, helping them maintain electrical circuit integrity during specified fire exposure conditions.

2. Is BFOU cable fire-resistant?

Yes. BFOU cables are designed for fire-resistant applications and can maintain electrical continuity during applicable fire-resistance testing, such as the relevant IEC 60331 test.

3. Is RFOU cable fire-resistant?

RFOU cables are flame-retardant rather than fire-resistant in the circuit-integrity sense. They help prevent the spread of flames but are not designed to guarantee continued electrical operation during direct fire exposure.

4. What is Mica Glass Tape in BFOU cables?

Mica Glass Tape is a specialised insulating fire-barrier material wrapped around the conductors. It helps protect the conductor insulation system during fire exposure and supports electrical continuity under specified test conditions.

5. Are RFOU and BFOU cables suitable for offshore applications?

Yes. Both cable types are designed for demanding marine and offshore installations, including oil and gas platforms, ships, and other fixed offshore electrical systems, when manufactured and certified to the required specifications.

6. Which cable is better for emergency shutdown systems?

BFOU cables are generally the appropriate choice when the emergency shutdown system requires electrical circuit integrity during fire exposure. The final selection must follow the project's approved safety and cable specifications.

7. What is the difference between RFOU and BFOU instrumentation cables?

Both can be used for instrumentation and communication applications. The main difference is that BFOU instrumentation cables incorporate an additional Mica Glass Tape fire barrier to support circuit integrity during specified fire conditions, whereas RFOU instrumentation cables provide flame-retardant performance.

8. What does NEK 606 mean in offshore cable specifications?

NEK TS 606 is a technical specification covering cables for offshore installations. It addresses cable construction and performance requirements relevant to demanding offshore environments, including fire performance, halogen-free materials, and resistance to drilling mud.